Franklin AIM Manual

AIM Manual

Motor Maintenance » Single-Phase Motors and Controls (Page 51)

Integral hp Control Box Parts

Table 51 Integral Horsepower Control Box Parts 60 Hz
MOTOR SIZEMOTOR
RATING HP
CONTROL BOX (1)
MODEL NO.
CAPACITORS
PART NO. (2)
MFD.VOLTSQTY.OVERLOAD (2)
PART NO.
RELAY (3)
PART NO.
CONTRACTOR (2)
PART NO.
4"1 - 1.5
STANDARD
282 300 8110
(See Note 5)
275 464 113 S
155 328 102 R
105-126
10
220
370
1
1
275 411 107155 031 102
282 300 8110
(See Note 5)
275 464 137 S
155 328 101 R
105-126
15
220
370
1
1
275 411 114 S
275 411 113 M
155 031 102
282 300 8610275 464 113 S
155 328 101 R
105-126
15
220
370
1
1
None
(See Note 4)
155 031 102
4"2
STANDARD
282 301 8110275 464 137 S
155 328 103 R
105-126
20
220
370
1
1
275 411 117 S
275 411 113 M
155 031 102
4"2
DELUXE
282 301 8310275 464 137 S
155 328 103 R
105-126
20
220
370
1
1
275 411 117 S
275 411 113 M
155 031 102155 325 102 L
4"3
STANDARD
282 302 8110275 463 123 S
155 327 109 R
208-250
45
220
370
1
1
275 411 118 S
275 411 115 M
155 031 102
4"3
DELUXE
282 302 8310275 463 123 S
155 327 109 R
208-250
45
220
370
1
1
275 411 118 S
275 411 115 M
155 031 102155 325 102 L
4" & 6"5
STANDARD
282 113 8110275 468 118 S
155 327 114 R
216-259
40
330
370
1
2
275 411 119 S
275 406 102 M
155 031 601
4" & 6"5
DELUXE
282 113 9310 275 468 118 S
155 327 114 R
216-259
40
330
370
1
2
275 411 119 S
275 406 102 M
155 031 601155 326 101 L
6"7.5
STANDARD
282 201 9210275 468 119 S
275 468 117 S
155 327 109 R
270-324
130-154
45
330
330
370
1
1
1
275 411 102 S
275 406 122 M
155 031 601
6"7.5
DELUXE
282 201 9310275 468 119 S
275 468 117 S
155 327 109 R
270-324
130-154
45
330
330
370
1
1
1
275 411 102 S
275 406 121 M
155 031 601155 326 102 L
6"10
STANDARD
282 202 9210275 468 119 S
275468 120 S
155 327 102 R
270-324
350-420
35
330
330
370
1
1
2
275 406 103 S
155 409 101 M
155 031 601
6"10
STANDARD
282 202 9230275 468 119 S
155 327 102 R
270-324
35
330
370
2
2
275 406 103 S
155 409 101 M
155 031 601
6"10
DELUXE
282 202 9310275 468 119 S
275468 120 S
155 327 102 R
270-324
350-420
35
330
330
370
1
1
2
275 406 103 S
155 409 101 M
155 031 601155 326 102 L
6"10
DELUXE
282 202 9330275 468 119 S
155 327 102 R
270-324
35
330
370
2
2
275 406 103 S
155 409 101 M
155 031 601155 326 102 L
6"15
DELUXE
282 203 9310275 468 120 S
155 327 109 R
350-420
45
330
370
2
3
275 406 103 S
155 409 102 M
155 031 601155 429 101 L
6"15
DELUXE
282 203 9330275 468 119 S
155 327 109 R
270-324
45
330
370
2
3
275 406 103 S
155 409 102 M
155 031 601155 429 101 L
6"15
X-LARGE
282 203 9621275 468 119 S
155 327 109 R
270-324
45
330
370
2
3
275 406 103 S
155 409 102 M
155 031 601
2 required
155 429 101 L
  • FOOTNOTES:
  • (1) Surge arrestors 150 814 902 are suitable for all control boxes.
  • (2) S = Start, M = Main, L = Line, R = Run. Deluxe = Control box with line contactor.
  • (3) For 208-volt systems or where line voltage is between 200 volts and 210 volts, a low voltage relay is required. On 3 hp and smaller control boxes use relay part 155 031 103 in place of 155 031 102 and use the next larger cable size than specified in the 230-volt table. On 5 hp and larger use relay 155 031 602 in place of 155 031 601 and next larger wire. Boost transformers per page 15 are an alternative to special relays and cable.
  • (4) Control box model 282 300 8610 is designed for use with motors having internal overload protectors. If used with a 1.5 hp motor manufactured prior to date code 06H18, Overload/Capacitor Kit 305 388 901 is required.
  • (5) Control box model 282 300 8110 with date code 11C19 (March 2011) and newer contain 15 MFD run capacitor and both start and run overloads. This box is designed for use with any Franklin 1.5 hp motor.